Zigbee2MQTTZigbee2MQTT
  • Getting started
  • Supported Adapters
  • Supported Devices
  • Installation
  • Configuration
  • Usage
  • FAQ
Devices
  • Zigbee

    • Zigbee network
    • Improve network range and stability
    • Sniff Zigbee traffic
    • Create a CC2530 router
  • Support new devices

    • Support new devices
    • Support new Tuya devices
    • Find Tuya Data Points
  • Remote Adapter

    • Connect to a remote adapter
    • Connect to a remote Sonoff ZBBridge
  • More

    • 3D cases
    • External converters
    • External extensions
    • Switch to the dev branch
    • Get Tuya and Xiaomi OTA url
  • Forum
  • Discord
  • Issues
  • Donate
GitHub
GitHub (docs)
  • Getting started
  • Supported Adapters
  • Supported Devices
  • Installation
  • Configuration
  • Usage
  • FAQ
Devices
  • Zigbee

    • Zigbee network
    • Improve network range and stability
    • Sniff Zigbee traffic
    • Create a CC2530 router
  • Support new devices

    • Support new devices
    • Support new Tuya devices
    • Find Tuya Data Points
  • Remote Adapter

    • Connect to a remote adapter
    • Connect to a remote Sonoff ZBBridge
  • More

    • 3D cases
    • External converters
    • External extensions
    • Switch to the dev branch
    • Get Tuya and Xiaomi OTA url
  • Forum
  • Discord
  • Issues
  • Donate
GitHub
GitHub (docs)

Arteco ZS-300Z

ModelZS-300Z
VendorArteco
DescriptionSoil moisture sensor
Exposessoil_moisture, soil_calibration, soil_moisture_warning, soil_moisture_warning_threshold, soil_sampling, temperature, temperature_calibration, humidity, humidity_calibration, illuminance, illuminance_calibration, water_warning, battery_state
PictureArteco ZS-300Z

Options

How to use device type specific configuration

  • time_start: Reply to Tuya-specific time synchronization requests: "1970" - Reply with seconds since 1970/01/01 (recommended, should stop the device from asking), "2000" - Reply with seconds since 2000/01/01 (use if the weekday is wrong with 1970), "off" - Don't reply (use if replying causes too much traffic). Default for this device: "off". The value must be one of 1970, 2000, off

  • soil_moisture_calibration: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.

  • soil_moisture_precision: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a maximum value of 3

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a maximum value of 3

  • humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.

  • humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a maximum value of 3

  • illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.

Exposes

Soil moisture (numeric)

Measured soil moisture value. Value can be found in the published state on the soil_moisture property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.

Soil moisture calibration (numeric)

Offset for measured soil moisture. Value can be found in the published state on the soil_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"soil_calibration": VALUE}. The minimal value is -30 and the maximum value is 30. The unit of this value is %.

Soil moisture warning (binary)

True when soil moisture is below the configured warning threshold. Value can be found in the published state on the soil_moisture_warning property. It's not possible to read (/get) or write (/set) this value. If value equals true soil moisture warning is ON, if false OFF.

Soil moisture warning threshold (numeric)

Soil moisture percentage below which the soil moisture warning activates. Value can be found in the published state on the soil_moisture_warning_threshold property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"soil_moisture_warning_threshold": VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Soil sampling interval (numeric)

Time interval between soil samplings. Value can be found in the published state on the soil_sampling property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"soil_sampling": VALUE}. The minimal value is 5 and the maximum value is 3600. The unit of this value is s.

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Temperature calibration (numeric)

Temperature calibration. Value can be found in the published state on the temperature_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_calibration": VALUE}. The minimal value is -2 and the maximum value is 2. The unit of this value is °C.

Humidity (numeric)

Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.

Humidity calibration (numeric)

Humidity calibration. Value can be found in the published state on the humidity_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_calibration": VALUE}. The minimal value is -30 and the maximum value is 30. The unit of this value is %.

Illuminance (numeric)

Measured illuminance. Value can be found in the published state on the illuminance property. It's not possible to read (/get) or write (/set) this value. The unit of this value is lx.

Illuminance calibration (numeric)

Illuminance calibration. Value can be found in the published state on the illuminance_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"illuminance_calibration": VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is lx.

Water warning (enum)

Water shortage warning. Value can be found in the published state on the water_warning property. It's not possible to read (/get) or write (/set) this value. The possible values are: none, alarm.

Battery state (enum)

low: 16.67%, middle:16.68-83.33%, high: 83.34-100%. Value can be found in the published state on the battery_state property. It's not possible to read (/get) or write (/set) this value. The possible values are: low, middle, high.