To contribute to this page, edit the following file
Netvox Z809A #
Model | Z809A |
Vendor | Netvox |
Description | Power socket with power consumption monitoring |
Exposes | switch (state), power, current, voltage, linkquality |
Picture | ![]() |
Notes #
Pairing #
Factory reset by:
- Press and hold the Binding Key for 15 seconds. The network indicator will flash green 3 times (at the 3rd, the 10th, and the 15th second).
- After releasing the Binding Key, press the Switch Key within 2 seconds. The network indicator will rapidly flash green.
- After fast flashes, Z809A will reboot, and the restore is completed. The socket will automatically connect now.
Exposes #
Switch #
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Power (numeric) #
Instantaneous measured power.
Value can be found in the published state on the power
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is W
.
Current (numeric) #
Instantaneous measured electrical current.
Value can be found in the published state on the current
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is A
.
Voltage (numeric) #
Measured electrical potential value.
Value can be found in the published state on the voltage
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is V
.
Linkquality (numeric) #
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.
Manual Home Assistant configuration #
Although Home Assistant integration through MQTT discovery is preferred, manual integration is possible with the following configuration:
switch:
- platform: "mqtt"
state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
availability_topic: "zigbee2mqtt/bridge/state"
payload_off: "OFF"
payload_on: "ON"
value_template: "{{ value_json.state }}"
command_topic: "zigbee2mqtt/<FRIENDLY_NAME>/set"
sensor:
- platform: "mqtt"
state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
availability_topic: "zigbee2mqtt/bridge/state"
value_template: "{{ value_json.power }}"
unit_of_measurement: "W"
device_class: "power"
sensor:
- platform: "mqtt"
state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
availability_topic: "zigbee2mqtt/bridge/state"
value_template: "{{ value_json.current }}"
unit_of_measurement: "A"
device_class: "current"
sensor:
- platform: "mqtt"
state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
availability_topic: "zigbee2mqtt/bridge/state"
value_template: "{{ value_json.voltage }}"
unit_of_measurement: "V"
device_class: "voltage"
sensor:
- platform: "mqtt"
state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
availability_topic: "zigbee2mqtt/bridge/state"
value_template: "{{ value_json.linkquality }}"
unit_of_measurement: "lqi"
icon: "mdi:signal"