Legrand WNAL50/WNRL50

ModelWNAL50/WNRL50
VendorLegrand
DescriptionSmart dimmer switch with Netatmo
Exposeslight (state, brightness), ballast_minimum_level, ballast_maximum_level, device_mode, led_in_dark, led_if_on, power_on_behavior, linkquality
PictureLegrand WNAL50/WNRL50

Options

How to use device type specific configuration

  • transition: Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to 0 (no transition). The value must be a number with a minimum value of 0

  • state_action: State actions will also be published as 'action' when true (default false). The value must be true or false

Exposes

Light

This light supports the following features: state, brightness.

  • state: To control the state publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the state send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.
  • brightness: To control the brightness publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"brightness": VALUE} where VALUE is a number between 0 and 254. To read the brightness send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"brightness": ""}.

On with timed off

When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time to the payload which is the time in seconds the state should remain on. Additionnaly an off_wait_time property can be added to the payload to specify the cooldown time in seconds when the light will not answer to other on with timed off commands. Support depend on the light firmware. Some devices might require both on_time and off_wait_time to work Examples : {"state" : "ON", "on_time": 300}, {"state" : "ON", "on_time": 300, "off_wait_time": 120}.

Ballast minimum level (numeric)

Specifies the minimum brightness value. Value can be found in the published state on the ballast_minimum_level property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"ballast_minimum_level": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"ballast_minimum_level": NEW_VALUE}. The minimal value is 1 and the maximum value is 254.

Ballast maximum level (numeric)

Specifies the maximum brightness value. Value can be found in the published state on the ballast_maximum_level property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"ballast_maximum_level": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"ballast_maximum_level": NEW_VALUE}. The minimal value is 1 and the maximum value is 254.

Device mode (binary)

Allow the device to change brightness. Value can be found in the published state on the device_mode property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"device_mode": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"device_mode": NEW_VALUE}. If value equals dimmer_on device mode is ON, if dimmer_off OFF.

Led in dark (binary)

Enables the LED when the light is turned off, allowing to see the switch in the dark. Value can be found in the published state on the led_in_dark property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"led_in_dark": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"led_in_dark": NEW_VALUE}. If value equals ON led in dark is ON, if OFF OFF.

Led if on (binary)

Enables the LED when the light is turned on. Value can be found in the published state on the led_if_on property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"led_if_on": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"led_if_on": NEW_VALUE}. If value equals ON led if on is ON, if OFF OFF.

Power-on behavior (enum)

Controls the behavior when the device is powered on after power loss. If you get an UNSUPPORTED_ATTRIBUTE error, the device does not support it.. Value can be found in the published state on the power_on_behavior property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"power_on_behavior": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_on_behavior": NEW_VALUE}. The possible values are: off, previous, on.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.