Tuya TS0601_soil_2
| Model | TS0601_soil_2 |
| Vendor | Tuya |
| Description | Soil sensor |
| Exposes | soil_moisture, temperature, temperature_f, temperature_sensitivity, humidity_sensitivity, temperature_alarm, humidity_alarm, max_temperature_alarm, min_temperature_alarm, max_humidity_alarm, min_humidity_alarm, schedule_periodic, battery, battery_state |
| Picture | ![]() |
Options
How to use device type specific configuration
soil_moisture_calibration: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.soil_moisture_precision: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3
Exposes
Soil moisture (numeric)
Measured soil moisture value. Value can be found in the published state on the soil_moisture property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.
Temperature (numeric)
Soil temperature. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The minimal value is -10 and the maximum value is 60. The unit of this value is °C.
Temperature f (numeric)
Soil temperature. Value can be found in the published state on the temperature_f property. It's not possible to read (/get) or write (/set) this value. The minimal value is 14 and the maximum value is 140. The unit of this value is °F.
Temperature sensitivity (numeric)
Temperature sensitivity. Value can be found in the published state on the temperature_sensitivity property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_sensitivity": NEW_VALUE}. The minimal value is 0.3 and the maximum value is 1. The unit of this value is °C.
Humidity sensitivity (numeric)
Humidity sensitivity. Value can be found in the published state on the humidity_sensitivity property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_sensitivity": NEW_VALUE}. The minimal value is 1 and the maximum value is 5. The unit of this value is %.
Temperature alarm (enum)
Temperature alarm state. Value can be found in the published state on the temperature_alarm property. It's not possible to read (/get) or write (/set) this value. The possible values are: lower_alarm, upper_alarm, cancel.
Humidity alarm (enum)
Humidity alarm state. Value can be found in the published state on the humidity_alarm property. It's not possible to read (/get) or write (/set) this value. The possible values are: lower_alarm, upper_alarm, cancel.
Max temperature alarm (numeric)
Upper temperature limit. Value can be found in the published state on the max_temperature_alarm property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"max_temperature_alarm": NEW_VALUE}. The minimal value is 0 and the maximum value is 60. The unit of this value is °C.
Min temperature alarm (numeric)
Lower temperature limit. Value can be found in the published state on the min_temperature_alarm property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"min_temperature_alarm": NEW_VALUE}. The minimal value is 0 and the maximum value is 60. The unit of this value is °C.
Max humidity alarm (numeric)
Upper humidity limit. Value can be found in the published state on the max_humidity_alarm property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"max_humidity_alarm": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Min humidity alarm (numeric)
Lower humidity limit. Value can be found in the published state on the min_humidity_alarm property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"min_humidity_alarm": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Schedule periodic (numeric)
Report sensitivity. Value can be found in the published state on the schedule_periodic property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"schedule_periodic": NEW_VALUE}. The minimal value is 5 and the maximum value is 60. The unit of this value is min.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Battery state (enum)
State of the battery. Value can be found in the published state on the battery_state property. It's not possible to read (/get) or write (/set) this value. The possible values are: low, medium, high.