Titan Products TPZRCO2HT-Z3

ModelTPZRCO2HT-Z3
VendorTitan Products
DescriptionRoom CO2, humidity & temperature sensor
Exposesvoltage, battery_low, humidity, temperature, co2, linkquality
PictureTitan Products TPZRCO2HT-Z3

Options

How to use device type specific configuration

  • humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.

  • humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • co2_calibration: Calibrates the co2 value (absolute offset), takes into effect on next report of device. The value must be a number.

Exposes

Voltage (numeric)

Voltage of the battery in millivolts. Value can be found in the published state on the voltage property. It's not possible to read (/get) or write (/set) this value. The unit of this value is mV.

Battery low (binary)

Indicates if the battery of this device is almost empty. Value can be found in the published state on the battery_low property. It's not possible to read (/get) or write (/set) this value. If value equals true battery low is ON, if false OFF.

Humidity (numeric)

Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.

CO2 (numeric)

The measured CO2 (carbon dioxide) value. Value can be found in the published state on the co2 property. It's not possible to read (/get) or write (/set) this value. The unit of this value is ppm.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.