Tuya SZTH02
Model | SZTH02 |
Vendor | Tuya |
Description | Temperature and humidity sensor |
Exposes | temperature, humidity, battery_state, temperature_unit, linkquality |
Picture |
Options
How to use device type specific configuration
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Battery state (enum)
State of the battery. Value can be found in the published state on the battery_state
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: low
, medium
, high
.
Temperature unit (enum)
Temperature unit. Value can be found in the published state on the temperature_unit
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_unit": NEW_VALUE}
. The possible values are: celsius
, fahrenheit
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.