Sunricher SR-ZG9001K2-DIM2
Model | SR-ZG9001K2-DIM2 |
Vendor | Sunricher |
Description | Zigbee 2 button wall switch |
Exposes | battery, action, linkquality |
Picture |
Options
How to use device type specific configuration
simulated_brightness
: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Example:
simulated_brightness:
delta: 20 # delta per interval, default = 20
interval: 200 # interval in milliseconds, default = 200
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Action (enum)
Triggered action (e.g. a button click). Value can be found in the published state on the action
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: on_1
, off_1
, stop_1
, brightness_move_up_1
, brightness_move_down_1
, brightness_stop_1
, on_2
, off_2
, stop_2
, brightness_move_up_2
, brightness_move_down_2
, brightness_stop_2
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.