TuYa SPM02V2

ModelSPM02V2
VendorTuYa
DescriptionSmart energy monitor for 3P+N system
Exposesvoltage_a, voltage_b, voltage_c, power_a, power_b, power_c, current_a, current_b, current_c, energy, produced_energy, power_factor, power, ac_frequency, linkquality
PictureTuYa SPM02V2

Options

How to use device type specific configuration

  • energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.

  • energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.

  • power_precision: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

Exposes

Voltage a (numeric)

Measured electrical potential value (phase A). Value can be found in the published state on the voltage_a property. It's not possible to read (/get) or write (/set) this value. The unit of this value is V.

Voltage b (numeric)

Measured electrical potential value (phase B). Value can be found in the published state on the voltage_b property. It's not possible to read (/get) or write (/set) this value. The unit of this value is V.

Voltage c (numeric)

Measured electrical potential value (phase C). Value can be found in the published state on the voltage_c property. It's not possible to read (/get) or write (/set) this value. The unit of this value is V.

Power a (numeric)

Instantaneous measured power (phase A). Value can be found in the published state on the power_a property. It's not possible to read (/get) or write (/set) this value. The unit of this value is W.

Power b (numeric)

Instantaneous measured power (phase B). Value can be found in the published state on the power_b property. It's not possible to read (/get) or write (/set) this value. The unit of this value is W.

Power c (numeric)

Instantaneous measured power (phase C). Value can be found in the published state on the power_c property. It's not possible to read (/get) or write (/set) this value. The unit of this value is W.

Current a (numeric)

Instantaneous measured electrical current (phase A). Value can be found in the published state on the current_a property. It's not possible to read (/get) or write (/set) this value. The unit of this value is A.

Current b (numeric)

Instantaneous measured electrical current (phase B). Value can be found in the published state on the current_b property. It's not possible to read (/get) or write (/set) this value. The unit of this value is A.

Current c (numeric)

Instantaneous measured electrical current (phase C). Value can be found in the published state on the current_c property. It's not possible to read (/get) or write (/set) this value. The unit of this value is A.

Energy (numeric)

Total forward active energy. Value can be found in the published state on the energy property. It's not possible to read (/get) or write (/set) this value. The unit of this value is kWh.

Produced energy (numeric)

Total reverse active energy. Value can be found in the published state on the produced_energy property. It's not possible to read (/get) or write (/set) this value. The unit of this value is kWh.

Power factor (numeric)

Instantaneous measured power factor. Value can be found in the published state on the power_factor property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.

Power (numeric)

Instantaneous measured power. Value can be found in the published state on the power property. It's not possible to read (/get) or write (/set) this value. The unit of this value is W.

AC frequency (numeric)

Measured electrical AC frequency. Value can be found in the published state on the ac_frequency property. It's not possible to read (/get) or write (/set) this value. The unit of this value is Hz.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.