Tuya SPM01V2
| Model | SPM01V2 |
| Vendor | Tuya |
| Description | Smart energy monitor for 1P+N system |
| Exposes | voltage, power, current, energy, produced_energy, power_factor, ac_frequency, data_report_duration |
| Picture | ![]() |
Options
How to use device type specific configuration
voltage_calibration: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.voltage_precision: Number of digits after decimal point for voltage, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a with a maximum value of3power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.power_precision: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a with a maximum value of3current_calibration: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.current_precision: Number of digits after decimal point for current, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a with a maximum value of3energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a with a maximum value of3ac_frequency_calibration: Calibrates the ac_frequency value (absolute offset), takes into effect on next report of device. The value must be a number.ac_frequency_precision: Number of digits after decimal point for ac_frequency, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a with a maximum value of3
Exposes
Voltage (numeric)
Measured electrical potential value. Value can be found in the published state on the voltage property. It's not possible to read (/get) or write (/set) this value. The unit of this value is V.
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power property. It's not possible to read (/get) or write (/set) this value. The unit of this value is W.
Current (numeric)
Instantaneous measured electrical current. Value can be found in the published state on the current property. It's not possible to read (/get) or write (/set) this value. The unit of this value is A.
Energy (numeric)
Total forward active energy. Value can be found in the published state on the energy property. It's not possible to read (/get) or write (/set) this value. The unit of this value is kWh.
Produced energy (numeric)
Total reverse active energy. Value can be found in the published state on the produced_energy property. It's not possible to read (/get) or write (/set) this value. The unit of this value is kWh.
Power factor (numeric)
Instantaneous measured power factor. Value can be found in the published state on the power_factor property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.
AC frequency (numeric)
Measured electrical AC frequency. Value can be found in the published state on the ac_frequency property. It's not possible to read (/get) or write (/set) this value. The unit of this value is Hz.
Data report duration (numeric)
WARNING: You must update device firmware to V3.1.3 before changing this setting! Use Tuya gateway/app to update firmware. Data report duration set (Threshold value range 30~3600 seconds). Value will not be published in the state. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"data_report_duration": NEW_VALUE}. The minimal value is 30 and the maximum value is 3600.