Zigbee2MQTTZigbee2MQTT
  • Getting started
  • Supported Adapters
  • Supported Devices
  • Installation
  • Configuration
  • Usage
  • FAQ
Devices
  • Zigbee

    • Zigbee network
    • Improve network range and stability
    • Secure your Zigbee network
    • Sniff Zigbee traffic
    • Create a CC2530 router
  • Support new devices

    • Support new devices
    • Support new Tuya devices
    • Find Tuya Data Points
  • Remote Adapter

    • Connect to a remote adapter
    • Connect to a remote Sonoff ZBBridge
  • More

    • 3D cases
    • External converters
    • External extensions
    • Switch to the dev branch
    • Get Tuya and Xiaomi OTA url
  • Forum
  • Discord
  • Issues
  • Donate
GitHub
GitHub (docs)
  • Getting started
  • Supported Adapters
  • Supported Devices
  • Installation
  • Configuration
  • Usage
  • FAQ
Devices
  • Zigbee

    • Zigbee network
    • Improve network range and stability
    • Secure your Zigbee network
    • Sniff Zigbee traffic
    • Create a CC2530 router
  • Support new devices

    • Support new devices
    • Support new Tuya devices
    • Find Tuya Data Points
  • Remote Adapter

    • Connect to a remote adapter
    • Connect to a remote Sonoff ZBBridge
  • More

    • 3D cases
    • External converters
    • External extensions
    • Switch to the dev branch
    • Get Tuya and Xiaomi OTA url
  • Forum
  • Discord
  • Issues
  • Donate
GitHub
GitHub (docs)

Aqara SJCGQ13LM

ModelSJCGQ13LM
VendorAqara
DescriptionWater leak sensor E1
Exposeswater_leak, battery, battery_low, voltage, device_temperature, power_outage_count
PictureAqara SJCGQ13LM

Notes

Battery

Uses CR2032 battery.

Pairing

Press and hold the reset button by pressing hard on the top of the device (water drop logo) for +- 5 seconds (until the blue light inside the device, under the water drop starts blinking). After this the device will automatically join.

OTA updates

This device supports OTA updates, for more information see OTA updates.

Options

How to use device type specific configuration

  • device_temperature_calibration: Calibrates the device_temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

Exposes

Water leak (binary)

Indicates whether the device detected a water leak. Value can be found in the published state on the water_leak property. It's not possible to read (/get) or write (/set) this value. If value equals true water leak is ON, if false OFF.

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Battery low (binary)

Indicates if the battery of this device is almost empty. Value can be found in the published state on the battery_low property. It's not possible to read (/get) or write (/set) this value. If value equals true battery low is ON, if false OFF.

Voltage (numeric)

Voltage of the battery in millivolts. Value can be found in the published state on the voltage property. It's not possible to read (/get) or write (/set) this value. The unit of this value is mV.

Device temperature (numeric)

Temperature of the device. Value can be found in the published state on the device_temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Power outage count (numeric)

Number of power outages. Value can be found in the published state on the power_outage_count property. It's not possible to read (/get) or write (/set) this value.