NodOn SIN-4-FP-20
Model | SIN-4-FP-20 |
Vendor | NodOn |
Description | Pilot wire heating module |
Exposes | power, energy, pilot_wire_mode, linkquality |
Picture |
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
Exposes
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is W
.
Energy (numeric)
Sum of consumed energy. Value can be found in the published state on the energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Pilot wire mode (enum)
Controls the target temperature of the heater, with respect to the temperature set on that heater. Possible values: comfort (target temperature = heater set temperature) eco (target temperature = heater set temperature - 3.5°C), frost_protection (target temperature = 7 to 8°C), off (heater stops heating), and the less commonly used comfort_-1 (target temperature = heater set temperature - 1°C), comfort_-2 (target temperature = heater set temperature - 2°C),.. Value can be found in the published state on the pilot_wire_mode
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"pilot_wire_mode": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"pilot_wire_mode": NEW_VALUE}
. The possible values are: comfort
, eco
, frost_protection
, off
, comfort_-1
, comfort_-2
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.