OWON PCT512
Model | PCT512 |
Vendor | OWON |
Description | Thermostat |
Exposes | climate (system_mode, local_temperature, running_state, occupied_heating_setpoint), occupancy, humidity |
Picture | ![]() |
Options
How to use device type specific configuration
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
no_occupancy_since
: Sends a message after the last time no occupancy (occupancy: false) was detected. When setting this for example to [10, 60] a{"no_occupancy_since": 10}
will be send after 10 seconds and a{"no_occupancy_since": 60}
after 60 seconds. The value must be a list of [object Object].
Exposes
Climate
This climate device supports the following features: system_mode
, local_temperature
, running_state
, occupied_heating_setpoint
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.running_state
: The current running state. Possible values are:heat
,idle
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"running_state": ""}
.
Occupancy (binary)
Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"occupancy": ""}
. It's not possible to write (/set
) this value. If value equals true
occupancy is ON, if false
OFF.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"humidity": ""}
. It's not possible to write (/set
) this value. The unit of this value is %
.