To contribute to this page, edit the following file

Lupus LS12128 #

Model LS12128
Vendor Lupus
Description Roller shutter
Exposes cover (state, position), linkquality
Picture Lupus LS12128

Notes #

Pairing/runtime calibration #

  1. Open shutter completely
  2. Make sure none of the physical button of the corresponding wall switch is left pressed down
  3. Press the LUPUS relay connection button 3-10s
  4. LED will start to blink
  5. At a certain point the LS12128 will reconnect to the zigbee coordinator (you hear a “click”) but it will still blink = it expects to learn closing time and opening time
  6. Press down button
  7. Just when the shutter is fully closed press “up” button (sometimes twice necessary).
  8. Just when the shutter is fully opened press “down” button (or release up button)
  9. Relay will now have learned how long it takes to travel top-bottom and vice-et-versa (youhear a “click” telling relay circuit is open) Note: device only connect to channels 11, 15, 20 or 25

Device type specific configuration #

How to use device type specific configuration

OTA updates #

This device supports OTA updates, for more information see OTA updates.

Exposes #

Cover #

The current state of this cover is in the published state under the state property (value is OPEN or CLOSE). To control this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "OPEN"}, {"state": "CLOSE"}, {"state": "STOP"}. To read the current state of this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}. To change the position publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"position": VALUE} where VALUE is a number between 0 and 100.

Linkquality (numeric) #

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.