Protection #

ZigBee 3.0, monitoring and cuts power if too high temperature or if overloaded.

Pairing #

Factory reset by press & hold the power button for 12 seconds. The LED is then starting to blink 3 times RED in intervals during pairing process.

Specs #

Manual #

Supplier’s manual

Device type specific configuration #

How to use device type specific configuration

Exposes #

Power (numeric) #

Instantaneous measured power. Value can be found in the published state on the power property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is W.

Current (numeric) #

Instantaneous measured electrical current. Value can be found in the published state on the current property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is A.

Voltage (numeric) #

Measured electrical potential value. Value can be found in the published state on the voltage property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is V.

Switch #

The current state of this switch is in the published state under the state property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.

Temperature (numeric) #

Measured temperature value. Value can be found in the published state on the temperature property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Linkquality (numeric) #