Bacchus Flower_Sensor_v2
Model | Flower_Sensor_v2 |
Vendor | Bacchus |
Description | Flower soil moisture sensor |
Exposes | soil_moisture, temperature, illuminance, report_delay, threshold, battery, voltage |
Picture | ![]() |
Options
How to use device type specific configuration
soil_moisture_calibration
: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.soil_moisture_precision
: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.illuminance_raw
: Expose the raw illuminance value. The value must betrue
orfalse
Exposes
Soil moisture (numeric)
Measured soil moisture value. Value can be found in the published state on the soil_moisture
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Illuminance (numeric)
Measured illuminance. Value can be found in the published state on the illuminance
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is lx
.
Report delay (numeric)
Reporting interval. Value can be found in the published state on the report_delay
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"report_delay": NEW_VALUE}
. The minimal value is 1
and the maximum value is 600
. The unit of this value is min
.
Threshold (numeric)
Reporting interval. Value can be found in the published state on the threshold
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"threshold": NEW_VALUE}
. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"battery": ""}
. It's not possible to write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Voltage (numeric)
Reported battery voltage in millivolts. Value can be found in the published state on the voltage
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"voltage": ""}
. It's not possible to write (/set
) this value. The unit of this value is mV
.