Bacchus Flower_Sensor_v2
| Model | Flower_Sensor_v2 |
| Vendor | Bacchus |
| Description | Flower soil moisture sensor |
| Exposes | soil_moisture, temperature, illuminance, report_delay, threshold, battery, voltage |
| Picture | ![]() |
Options
How to use device type specific configuration
soil_moisture_calibration: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.soil_moisture_precision: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a with a maximum value of3temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a with a maximum value of3illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.illuminance_raw: Expose the raw illuminance value. The value must betrueorfalse
Exposes
Soil moisture (numeric)
Measured soil moisture value. Value can be found in the published state on the soil_moisture property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.
Illuminance (numeric)
Measured illuminance. Value can be found in the published state on the illuminance property. It's not possible to read (/get) or write (/set) this value. The unit of this value is lx.
Report delay (numeric)
Reporting interval. Value can be found in the published state on the report_delay property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"report_delay": NEW_VALUE}. The minimal value is 1 and the maximum value is 600. The unit of this value is min.
Threshold (numeric)
Reporting interval. Value can be found in the published state on the threshold property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"threshold": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"battery": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Voltage (numeric)
Reported battery voltage in millivolts. Value can be found in the published state on the voltage property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"voltage": ""}. It's not possible to write (/set) this value. The unit of this value is mV.

