Philips 929002240401
Model | 929002240401 |
Vendor | Philips |
Description | Hue smart plug - EU |
Exposes | switch (state), linkquality |
Picture |
Notes
Pairing
Hold down power button (side of the switch) about 10 seconds, release once it blinks and then turns green.
Power-on behavior
This device allows you to set the power-on behavior. Note that this requires at least November/December '18 firmware update of the device. Send a MQTT command to zigbee2mqtt/FRIENDLY_NAME/set
with the following payload.
{
"hue_power_on_behavior": "on", // default, on, off, recover
"hue_power_on_brightness": 125, // same values as brightness
"hue_power_on_color_temperature": 280, // same values as color_temp
"hue_power_on_color": "#0000FF" // color in hex notation, e.g. #0000FF = blue
}
Attribute Value | Description |
---|---|
default | reset to factory default value |
on | bulb on after power loss with configured brightness, color-temperature and color |
off | bulb off after power loss |
recover | last running state after power loss |
Rules:
hue_power_on_behavior
value always has to be providedhue_power_on_brightness
,hue_power_on_color_temperature
andhue_power_on_color
can only be provided whenhue_power_on_behavior
=on
hue_power_on_color_temperature
andhue_power_on_color
cannot be provided together, only one can be set- When setting
hue_power_on_behavior
=on
, any not provided values will be reset to their factory defaults
Note: if hue_power_on_behavior
is set to off
, then the only way to turn the bulb on will be through a paired smart device (see pairing above). You will NOT be able to turn the bulb on by sequentially switching power on and off.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.