Centralite 4257050-ZHAC

Model4257050-ZHAC
VendorCentralite
Description3-Series smart dimming outlet
Exposeslight (state, brightness), power, voltage, current, linkquality
PictureCentralite 4257050-ZHAC

Options

How to use device type specific configuration

  • transition: Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to 0 (no transition). The value must be a number with a minimum value of 0

Exposes

Light

This light supports the following features: state, brightness.

  • state: To control the state publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the state send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.
  • brightness: To control the brightness publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"brightness": VALUE} where VALUE is a number between 0 and 254. To read the brightness send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"brightness": ""}.

Transition

For all of the above mentioned features it is possible to do a transition of the value over time. To do this add an additional property transition to the payload which is the transition time in seconds. Examples: {"brightness":156,"transition":3}, {"color_temp":241,"transition":1}.

Moving/stepping

Instead of setting a value (e.g. brightness) directly it is also possible to:

  • move: this will automatically move the value over time, to stop send value stop or 0.
  • step: this will increment/decrement the current value by the given one.

The direction of move and step can be either up or down, provide a negative value to move/step down, a positive value to move/step up. To do this send a payload like below to zigbee2mqtt/FRIENDLY_NAME/set

NOTE: brightness move/step will stop at the minimum brightness and won't turn on the light when it's off. In this case use brightness_move_onoff/brightness_step_onoff

{
  "brightness_move": -40, // Starts moving brightness down at 40 units per second
  "brightness_move": 0, // Stop moving brightness
  "brightness_step": 40 // Increases brightness by 40
}
1
2
3
4
5

Power (numeric)

Instantaneous measured power. Value can be found in the published state on the power property. It's not possible to read (/get) or write (/set) this value. The unit of this value is W.

Voltage (numeric)

Measured electrical potential value. Value can be found in the published state on the voltage property. It's not possible to read (/get) or write (/set) this value. The unit of this value is V.

Current (numeric)

Instantaneous measured electrical current. Value can be found in the published state on the current property. It's not possible to read (/get) or write (/set) this value. The unit of this value is A.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.