Konke 2AJZ4KPFT #
Model | 2AJZ4KPFT |
Vendor | Konke |
Description | Temperature and humidity sensor |
Exposes | temperature, humidity, battery, linkquality |
Picture | ![]() |
Notes #
Device type specific configuration #
How to use device type specific configuration
temperature_precision
: Controls the precision oftemperature
values, e.g.0
,1
or2
; default2
. To control the precision based on the temperature value set it to e.g.{30: 0, 10: 1}
, when temperature >= 30 precision will be 0, when temperature >= 10 precision will be 1.-
temperature_calibration
: Allows to manually calibrate temperature values, e.g.1
would add 1 degree to the temperature reported by the device; default0
. humidity_precision
: Controls the precision ofhumidity
values, e.g.0
,1
or2
; default2
. To control the precision based on the humidity value set it to e.g.{80: 0, 10: 1}
, when humidity >= 80 precision will be 0, when humidity >= 10 precision will be 1.
Important #
Konke devices only work on Zigbee channel 15, 20 and 25.
Exposes #
Temperature (numeric) #
Measured temperature value.
Value can be found in the published state on the temperature
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is °C
.
Humidity (numeric) #
Measured relative humidity.
Value can be found in the published state on the humidity
property.
It’s not possible to read (/get
) or write (/set
) this value.
The unit of this value is %
.
Battery (numeric) #
Remaining battery in %.
Value can be found in the published state on the battery
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 100
.
The unit of this value is %
.
Linkquality (numeric) #
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It’s not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.
Manual Home Assistant configuration #
Although Home Assistant integration through MQTT discovery is preferred, manual integration is possible with the following configuration:
sensor:
- platform: "mqtt"
state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
availability_topic: "zigbee2mqtt/bridge/state"
unit_of_measurement: "°C"
value_template: "{{ value_json.temperature }}"
device_class: "temperature"
sensor:
- platform: "mqtt"
state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
availability_topic: "zigbee2mqtt/bridge/state"
unit_of_measurement: "%"
value_template: "{{ value_json.humidity }}"
device_class: "humidity"
sensor:
- platform: "mqtt"
state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
availability_topic: "zigbee2mqtt/bridge/state"
unit_of_measurement: "%"
value_template: "{{ value_json.battery }}"
device_class: "battery"
sensor:
- platform: "mqtt"
state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
availability_topic: "zigbee2mqtt/bridge/state"
unit_of_measurement: "lqi"
value_template: "{{ value_json.linkquality }}"
icon: "mdi:signal"