Legrand 064882
Model | 064882 |
Vendor | Legrand |
Description | Cable outlet with pilot wire and consumption measurement |
Exposes | device_mode, cable_outlet_mode, switch (state), power, linkquality |
Picture | ![]() |
Options
How to use device type specific configuration
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Device_mode (binary)
Value can be found in the published state on the device_mode
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"device_mode": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"device_mode": NEW_VALUE}
. If value equals pilot_on
device_mode is ON, if pilot_off
OFF.
Cable_outlet_mode (enum)
Value can be found in the published state on the cable_outlet_mode
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"cable_outlet_mode": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"cable_outlet_mode": NEW_VALUE}
. The possible values are: comfort
, comfort-1
, comfort-2
, eco
, frost_protection
, off
.
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power": ""}
. It's not possible to write (/set
) this value. The unit of this value is W
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.