Tuya ZS-TYG3-SM-21Z
Model | ZS-TYG3-SM-21Z |
Vendor | Tuya |
Description | 2 gang smart switch with backlight and neutral wire |
Exposes | switch (state), backlight_mode, countdown, power_on_behavior, linkquality |
Picture |
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
. It's not possible to read (/get
) this value.
Switch (l1 endpoint)
The current state of this switch is in the published state under the state_l1
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l1": "ON"}
, {"state_l1": "OFF"}
or {"state_l1": "TOGGLE"}
. It's not possible to read (/get
) this value.
Switch (l2 endpoint)
The current state of this switch is in the published state under the state_l2
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l2": "ON"}
, {"state_l2": "OFF"}
or {"state_l2": "TOGGLE"}
. It's not possible to read (/get
) this value.
Backlight mode (binary)
Mode of the backlight. Value can be found in the published state on the backlight_mode
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"backlight_mode": NEW_VALUE}
. If value equals ON
backlight mode is ON, if OFF
OFF.
Countdown (numeric, l1 endpoint)
Countdown to turn device off after a certain time. Value can be found in the published state on the countdown_l1
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"countdown_l1": NEW_VALUE}
. The minimal value is 0
and the maximum value is 43200
. The unit of this value is s
.
Countdown (numeric, l2 endpoint)
Countdown to turn device off after a certain time. Value can be found in the published state on the countdown_l2
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"countdown_l2": NEW_VALUE}
. The minimal value is 0
and the maximum value is 43200
. The unit of this value is s
.
Power-on behavior (enum)
Controls the behavior when the device is powered on after power loss. If you get an UNSUPPORTED_ATTRIBUTE
error, the device does not support it.. Value can be found in the published state on the power_on_behavior
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
. The possible values are: off
, previous
, on
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.