Arteco ZS-SF00
| Model | ZS-SF00 |
| Vendor | Arteco |
| Description | Soil fertility sensor |
| Exposes | water_warning, soil_fertility_warning, battery, soil_moisture, soil_fertility, temperature, humidity, illuminance, soil_sampling, soil_calibration, humidity_calibration, illuminance_calibration, temperature_calibration, soil_warning, soil_fertility_warning_setting |
| Picture | ![]() |
Options
How to use device type specific configuration
time_start: Reply to Tuya-specific time synchronization requests: "1970" - Reply with seconds since 1970/01/01 (recommended, should stop the device from asking), "2000" - Reply with seconds since 2000/01/01 (use if the weekday is wrong with 1970), "off" - Don't reply (use if replying causes too much traffic). Default for this device: "off". The value must be one of1970,2000,offsoil_moisture_calibration: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.soil_moisture_precision: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Water warning (enum)
Water shortage warning. Value can be found in the published state on the water_warning property. It's not possible to read (/get) or write (/set) this value. The possible values are: none, alarm.
Soil fertility warning (enum)
Soil fertility warning. Value can be found in the published state on the soil_fertility_warning property. It's not possible to read (/get) or write (/set) this value. The possible values are: none, alarm.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Soil moisture (numeric)
Measured soil moisture value. Value can be found in the published state on the soil_moisture property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.
Soil fertility (numeric)
Soil fertility value,between 0-5000. Value can be found in the published state on the soil_fertility property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 5000. The unit of this value is μS/cm.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.
Illuminance (numeric)
Measured illuminance. Value can be found in the published state on the illuminance property. It's not possible to read (/get) or write (/set) this value. The unit of this value is lx.
Soil sampling interval (numeric)
Time interval between soil samplings. Value can be found in the published state on the soil_sampling property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"soil_sampling": VALUE}. The minimal value is 5 and the maximum value is 3600. The unit of this value is s.
Soil moisture calibration (numeric)
Offset for measured soil moisture. Value can be found in the published state on the soil_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"soil_calibration": VALUE}. The minimal value is -30 and the maximum value is 30. The unit of this value is %.
Humidity calibration (numeric)
Humidity calibration. Value can be found in the published state on the humidity_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_calibration": VALUE}. The minimal value is -30 and the maximum value is 30. The unit of this value is %.
Illuminance calibration (numeric)
Illuminance calibration. Value can be found in the published state on the illuminance_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"illuminance_calibration": VALUE}. The minimal value is -15 and the maximum value is 1000. The unit of this value is lux.
Temperature calibration (numeric)
Temperature calibration. Value can be found in the published state on the temperature_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_calibration": VALUE}. The minimal value is -2 and the maximum value is 2. The unit of this value is °C.
Soil warning (numeric)
Soil water shortage humidity value. Value can be found in the published state on the soil_warning property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"soil_warning": VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Soil fertility warning setting (numeric)
When the soil fertility value is lower than what threshold should a warning be issued. Value can be found in the published state on the soil_fertility_warning_setting property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"soil_fertility_warning_setting": VALUE}. The minimal value is 100 and the maximum value is 5000. The unit of this value is μS/cm.