Tuya TS0601_smoke_6
| Model | TS0601_smoke_6 |
| Vendor | Tuya |
| Description | Smoke sensor |
| Exposes | smoke, tamper, battery_state |
| Picture | ![]() |
Options
How to use device type specific configuration
time_start: Reply to Tuya-specific time synchronization requests: "1970" - Reply with seconds since 1970/01/01 (recommended, should stop the device from asking), "2000" - Reply with seconds since 2000/01/01 (use if the weekday is wrong with 1970), "off" - Don't reply (use if replying causes too much traffic). Default for this device: "off". The value must be one of1970,2000,off
Exposes
Smoke (binary)
Indicates whether the device detected smoke. Value can be found in the published state on the smoke property. It's not possible to read (/get) or write (/set) this value. If value equals true smoke is ON, if false OFF.
Tamper (binary)
Indicates whether the device is tampered. Value can be found in the published state on the tamper property. It's not possible to read (/get) or write (/set) this value. If value equals true tamper is ON, if false OFF.
Battery state (enum)
State of the battery. Value can be found in the published state on the battery_state property. It's not possible to read (/get) or write (/set) this value. The possible values are: low, medium, high.