TuYa TS0601_co2_sensor
Model | TS0601_co2_sensor |
Vendor | TuYa |
Description | NDIR co2 sensor |
Exposes | temperature, humidity, co2, linkquality |
Picture | ![]() |
Options
How to use device type specific configuration
temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.co2_precision
: Number of digits after decimal point for co2, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
co2_calibration
: Calibrates the co2 value (absolute offset), takes into effect on next report of device. The value must be a number.voc_precision
: Number of digits after decimal point for voc, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
voc_calibration
: Calibrates the voc value (absolute offset), takes into effect on next report of device. The value must be a number.formaldehyd_precision
: Number of digits after decimal point for formaldehyd, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
formaldehyd_calibration
: Calibrates the formaldehyd value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Co2 (numeric)
The measured CO2 (carbon dioxide) value. Value can be found in the published state on the co2
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is ppm
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.