TONGOU TO-Q-SY2-163JZT

ModelTO-Q-SY2-163JZT
VendorTONGOU
DescriptionSmart circuit breaker
Exposestemperature, temperature_threshold, temperature_breaker, power_threshold, power_breaker, over_current_threshold, over_current_breaker, over_voltage_threshold, over_voltage_breaker, under_voltage_threshold, under_voltage_breaker, switch (state), power_outage_memory, indicator_mode, power, current, voltage, energy, linkquality
PictureTONGOU TO-Q-SY2-163JZT

OTA updates

This device supports OTA updates, for more information see OTA updates.

Options

How to use device type specific configuration

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • power_calibration: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.

  • power_precision: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • current_calibration: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.

  • current_precision: Number of digits after decimal point for current, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • voltage_calibration: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.

  • voltage_precision: Number of digits after decimal point for voltage, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • energy_calibration: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.

  • energy_precision: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a with a maximum value of 3

  • state_action: State actions will also be published as 'action' when true (default false). The value must be true or false

Exposes

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Temperature threshold (numeric)

High temperature threshold. Value can be found in the published state on the temperature_threshold property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_threshold": NEW_VALUE}. The minimal value is 40 and the maximum value is 100. The unit of this value is *C.

Temperature breaker (binary)

High temperature breaker. Value can be found in the published state on the temperature_breaker property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_breaker": NEW_VALUE}. If value equals ON temperature breaker is ON, if OFF OFF.

Power threshold (numeric)

High power threshold. Value can be found in the published state on the power_threshold property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_threshold": NEW_VALUE}. The minimal value is 1 and the maximum value is 26. The unit of this value is kW.

Power breaker (binary)

High power breaker. Value can be found in the published state on the power_breaker property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_breaker": NEW_VALUE}. If value equals ON power breaker is ON, if OFF OFF.

Over current threshold (numeric)

Over-current threshold. Value can be found in the published state on the over_current_threshold property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"over_current_threshold": NEW_VALUE}. The minimal value is 1 and the maximum value is 64. The unit of this value is A.

Over current breaker (binary)

Over-current breaker. Value can be found in the published state on the over_current_breaker property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"over_current_breaker": NEW_VALUE}. If value equals ON over current breaker is ON, if OFF OFF.

Over voltage threshold (numeric)

Over-voltage threshold. Value can be found in the published state on the over_voltage_threshold property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"over_voltage_threshold": NEW_VALUE}. The minimal value is 220 and the maximum value is 265. The unit of this value is V.

Over voltage breaker (binary)

Over-voltage breaker. Value can be found in the published state on the over_voltage_breaker property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"over_voltage_breaker": NEW_VALUE}. If value equals ON over voltage breaker is ON, if OFF OFF.

Under voltage threshold (numeric)

Under-voltage threshold. Value can be found in the published state on the under_voltage_threshold property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"under_voltage_threshold": NEW_VALUE}. The minimal value is 76 and the maximum value is 240. The unit of this value is V.

Under voltage breaker (binary)

Under-voltage breaker. Value can be found in the published state on the under_voltage_breaker property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"under_voltage_breaker": NEW_VALUE}. If value equals ON under voltage breaker is ON, if OFF OFF.

Switch

The current state of this switch is in the published state under the state property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.

On with timed off

When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time to the payload which is the time in seconds the state should remain on. Additionnaly an off_wait_time property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depend on the switch firmware. Some devices might require both on_time and off_wait_time to work Examples : {"state" : "ON", "on_time": 300}, {"state" : "ON", "on_time": 300, "off_wait_time": 120}.

Power outage memory (enum)

Recover state after power outage. Value can be found in the published state on the power_outage_memory property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"power_outage_memory": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"power_outage_memory": NEW_VALUE}. The possible values are: on, off, restore.

Indicator mode (enum)

LED indicator mode. Value can be found in the published state on the indicator_mode property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"indicator_mode": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"indicator_mode": NEW_VALUE}. The possible values are: off, off/on, on/off, on.

Power (numeric)

Instantaneous measured power. Value can be found in the published state on the power property. It's not possible to read (/get) or write (/set) this value. The unit of this value is W.

Current (numeric)

Instantaneous measured electrical current. Value can be found in the published state on the current property. It's not possible to read (/get) or write (/set) this value. The unit of this value is A.

Voltage (numeric)

Measured electrical potential value. Value can be found in the published state on the voltage property. It's not possible to read (/get) or write (/set) this value. The unit of this value is V.

Energy (numeric)

Sum of consumed energy. Value can be found in the published state on the energy property. It's not possible to read (/get) or write (/set) this value. The unit of this value is kWh.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.