Rti-Tek STH1Z
| Model | STH1Z |
| Vendor | Rti-Tek |
| Description | Temperature and humidity sensor |
| Exposes | temperature, humidity, battery, temperature_unit, internal_temperature_calibration, internal_humidity_calibration, sample_interval, temperature_alarm_upper, temperature_alarm_lower, humidity_alarm_upper, humidity_alarm_lower, temperature_alarm_status, humidity_alarm_status, fault_status, dew_point, vpd, humidity_comfort, comfort_humidity_lower_limit, comfort_humidity_upper_limit, comfort_temperature_lower_limit, comfort_temperature_upper_limit |
| Picture | ![]() |
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3
Exposes
Temperature (numeric)
Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"humidity": ""}. It's not possible to write (/set) this value. The unit of this value is %.
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"battery": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Temperature unit (enum)
Value can be found in the published state on the temperature_unit property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_unit": NEW_VALUE}. The possible values are: celsius, fahrenheit.
Internal temperature calibration (numeric)
Value can be found in the published state on the internal_temperature_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"internal_temperature_calibration": NEW_VALUE}. The minimal value is -10 and the maximum value is 10. The unit of this value is °C.
Internal humidity calibration (numeric)
Value can be found in the published state on the internal_humidity_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"internal_humidity_calibration": NEW_VALUE}. The minimal value is -10 and the maximum value is 10. The unit of this value is %.
Sample interval (numeric)
Value can be found in the published state on the sample_interval property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"sample_interval": NEW_VALUE}. The minimal value is 1 and the maximum value is 3600. The unit of this value is s.
Temperature alarm upper (numeric)
Value can be found in the published state on the temperature_alarm_upper property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_alarm_upper": NEW_VALUE}. The minimal value is -30 and the maximum value is 60. The unit of this value is °C.
Temperature alarm lower (numeric)
Value can be found in the published state on the temperature_alarm_lower property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_alarm_lower": NEW_VALUE}. The minimal value is -30 and the maximum value is 60. The unit of this value is °C.
Humidity alarm upper (numeric)
Value can be found in the published state on the humidity_alarm_upper property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_alarm_upper": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Humidity alarm lower (numeric)
Value can be found in the published state on the humidity_alarm_lower property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_alarm_lower": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Temperature alarm status (enum)
Value can be found in the published state on the temperature_alarm_status property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"temperature_alarm_status": ""}. It's not possible to write (/set) this value. The possible values are: normal, low, high.
Humidity alarm status (enum)
Value can be found in the published state on the humidity_alarm_status property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"humidity_alarm_status": ""}. It's not possible to write (/set) this value. The possible values are: normal, low, high.
Fault status (text)
Value can be found in the published state on the fault_status property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"fault_status": ""}. It's not possible to write (/set) this value.
Dew point (numeric)
Value can be found in the published state on the dew_point property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.
Vpd (numeric)
Value can be found in the published state on the vpd property. It's not possible to read (/get) or write (/set) this value. The unit of this value is kPa.
Humidity comfort (enum)
Value can be found in the published state on the humidity_comfort property. It's not possible to read (/get) or write (/set) this value. The possible values are: dry, comfort, wet, normal.
Comfort humidity lower limit (numeric)
Value can be found in the published state on the comfort_humidity_lower_limit property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"comfort_humidity_lower_limit": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Comfort humidity upper limit (numeric)
Value can be found in the published state on the comfort_humidity_upper_limit property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"comfort_humidity_upper_limit": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Comfort temperature lower limit (numeric)
Value can be found in the published state on the comfort_temperature_lower_limit property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"comfort_temperature_lower_limit": NEW_VALUE}. The minimal value is -20 and the maximum value is 60. The unit of this value is °C.
Comfort temperature upper limit (numeric)
Value can be found in the published state on the comfort_temperature_upper_limit property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"comfort_temperature_upper_limit": NEW_VALUE}. The minimal value is -20 and the maximum value is 60. The unit of this value is °C.