Ubisys S1-R-2
Model | S1-R-2 |
Vendor | Ubisys |
Description | Power switch S1-R (Series 2) |
Exposes | identify, switch (state), power, energy, action, linkquality |
Picture |
Options
How to use device type specific configuration
measurement_poll_interval
: This device does not support reporting electric measurements so it is polled instead. The default poll interval is 60 seconds, set to -1 to disable. The value must be a number with a minimum value of-1
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
identify_timeout
: Sets the duration of the identification procedure in seconds (i.e., how long the device would flash).The value ranges from 1 to 30 seconds (default: 3). The value must be a number with a minimum value of1
and with a with a maximum value of30
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
simulated_brightness
: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Example:
simulated_brightness:
delta: 20 # delta per interval, default = 20
interval: 200 # interval in milliseconds, default = 200
Exposes
Identify (enum)
Initiate device identification. Value will not be published in the state. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"identify": NEW_VALUE}
. The possible values are: identify
.
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power": ""}
. It's not possible to write (/set
) this value. The unit of this value is W
.
Energy (numeric)
Sum of consumed energy. Value can be found in the published state on the energy
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"energy": ""}
. It's not possible to write (/set
) this value. The unit of this value is kWh
.
Action (enum)
Triggered action (e.g. a button click). Value can be found in the published state on the action
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: on_2
, on_3
, off_2
, off_3
, toggle_2
, toggle_3
, brightness_move_to_level_2
, brightness_move_to_level_3
, brightness_move_up_2
, brightness_move_up_3
, brightness_move_down_2
, brightness_move_down_3
, brightness_step_up_2
, brightness_step_up_3
, brightness_step_down_2
, brightness_step_down_3
, brightness_stop_2
, brightness_stop_3
, color_temperature_move_stop_2
, color_temperature_move_stop_3
, color_temperature_move_up_2
, color_temperature_move_up_3
, color_temperature_move_down_2
, color_temperature_move_down_3
, color_temperature_step_up_2
, color_temperature_step_up_3
, color_temperature_step_down_2
, color_temperature_step_down_3
, enhanced_move_to_hue_and_saturation_2
, enhanced_move_to_hue_and_saturation_3
, move_to_hue_and_saturation_2
, move_to_hue_and_saturation_3
, color_hue_step_up_2
, color_hue_step_up_3
, color_hue_step_down_2
, color_hue_step_down_3
, color_saturation_step_up_2
, color_saturation_step_up_3
, color_saturation_step_down_2
, color_saturation_step_down_3
, color_loop_set_2
, color_loop_set_3
, color_temperature_move_2
, color_temperature_move_3
, color_move_2
, color_move_3
, hue_move_2
, hue_move_3
, hue_stop_2
, hue_stop_3
, move_to_saturation_2
, move_to_saturation_3
, move_to_hue_2
, move_to_hue_3
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.