Heiman HS1SA-E-PLUS
| Model | HS1SA-E-PLUS |
| Vendor | Heiman |
| Description | Smart smoke alarm |
| Exposes | battery, identify, temperature, smoke, battery_low, test, fault_state, muted, trigger_selftest, temporary_mute, heartbeat_indicator, interconnectable, smoke_level, smoke_unit, chamber_contamination, link_available, siren_for_automation_only, temperature_offset, reported_packages, rejoin_count, reboot_count |
| Picture | ![]() |
Notes
Exposed values and controls
muted is a read-only silencing status, not a switch for disabling smoke detection. normal means no mute flags are set. Otherwise, the converter reports one or more of muted (general), alarm_muted, fault_muted, low_battery_muted, endoflife_muted, and warning_muted, separated by |. These distinguish which sounds are silenced; they do not mean the detector is permanently disabled. Not every firmware necessarily reports every flag.
temporary_mute is the separate remote hush control. Heiman confirms that, on HS1SA-E-PLUS firmware 2.2.0, it only works while a smoke alarm is active: requesting it while idle does not pre-emptively silence a future alarm. Use it after confirming that an alarm is false. The converter writes true as 1 and false as 0 to the mute-control attribute, but an explicit unmute action for false is not confirmed for this firmware; use muted to check the actual silencing status. The physical test/mute button also provides hush, but identical remote/button timing, the hush duration, and when persistent smoke makes the alarm sound again are not confirmed for this model.
| Entity | Meaning and use |
|---|---|
trigger_selftest, test | Request the built-in alarm self-check; test reports whether a test is running. This can exercise an interconnection automation as well. Test beeps have been observed on PLUS samples, but the complete internal checks are undocumented; a successful self-test alone does not establish smoke-sensing performance. |
heartbeat_indicator | Controls the periodic heartbeat LED indication during normal operation, useful for avoiding flashes in a bedroom. It is not a smoke-detection or sound control. Whether this setting also changes alarm/test LED indications is not confirmed. |
interconnectable, link_available | Read-only triggers for propagating this detector's event through an automation, not a capability or configuration switch. Both represent the same attribute: interconnectable is false for zero and true for a nonzero value; link_available identifies the event type. inactive means no linkage event; smoke_active, co_active, gas_active, and heat_active identify smoke, CO, gas, and heat events respectively in the shared protocol. These enum choices do not imply that this smoke-only model detects all four hazards. |
siren_for_automation_only | Lets an automation use the detector as a remotely triggered sounder: smoke_siren and co_siren select the built-in smoke and CO sound profiles; stop stops the automation siren. The CO profile does not add CO detection. This control is for sounding other alarms in response to an originating detector's linkage event. |
smoke_level, smoke_unit | Manufacturer-reported optical smoke level. The converter divides the reported level by 100 and exposes its unit separately: dB/m means optical attenuation in decibels per metre; %ft OBS means percent light obscuration per foot. These describe light loss through smoke, not a percentage of smoke in the air. The exposed 0–20 range is not a documented alarm threshold. No model-specific calibration, threshold, or guarantee of a strictly increasing response is documented; treat the level as diagnostic/trend information and use smoke for the detector's alarm decision. |
chamber_contamination | The detector's estimate of contamination in its optical sensing chamber: normal, then increasing severity from light_contamination through medium_contamination to critical_contamination. Deposits such as cooking grease and smoke particles can reduce sensitivity and increase false alarms. Useful for maintenance alerts; Heiman has not specified cleaning/replacement actions for each exposed level in the available PLUS documentation. Follow the supplied maintenance instructions. |
fault_state | normal means no mapped fault bits are set. The converter can report fault (general), open_circuit_fault, short_circuit_fault, and pollution_fault (contamination), joining simultaneous faults with |. These are fault categories, not identification of a particular failed component; which bits this firmware uses is undocumented. |
temperature_offset | A calibration offset in °C stored on the detector for its own temperature reporting. This is separate from Zigbee2MQTT's temperature_calibration option, which adjusts received readings in software. |
reported_packages, rejoin_count, reboot_count | Device diagnostic counters for reported Zigbee packets, network rejoins, and restarts. The converter describes reported_packages as a daily count, but does not define the day's boundary or reset rules. The time span, persistence, and reset rules of the other counters are also undocumented. Watch changes: repeated rejoins can help investigate connectivity, while unexpected restarts can help investigate power/device problems. |
Heiman describes interconnection on this model as Home Assistant/Zigbee2MQTT automation, rather than detectors directly triggering one another over Zigbee. The linkage triggers activate during self-test and real alarms, and become inactive when the originating alarm is hushed. An automation can use these transitions to start and stop the other detectors' siren_for_automation_only controls. Receiving a remote siren command does not itself establish local smoke or CO detection.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3identify_timeout: Sets the duration of the identification procedure in seconds (i.e., how long the device would flash).The value ranges from 1 to 30 seconds (default: 3). The value must be a number with a minimum value of1and with a maximum value of30
Exposes
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"battery": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Identify (enum)
Initiate device identification. Value will not be published in the state. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"identify": "VALUE"}. The possible values are: identify.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"temperature": ""}. It's not possible to write (/set) this value. The unit of this value is °C.
Smoke (binary)
Indicates whether the device detected smoke. Value can be found in the published state on the smoke property. It's not possible to read (/get) or write (/set) this value. If value equals true smoke is ON, if false OFF.
Battery low (binary)
Indicates whether the battery of the device is almost empty. Value can be found in the published state on the battery_low property. It's not possible to read (/get) or write (/set) this value. If value equals true battery low is ON, if false OFF.
Test (binary)
Indicates whether the device is currently performing a test. Value can be found in the published state on the test property. It's not possible to read (/get) or write (/set) this value. If value equals true test is ON, if false OFF.
Fault state (text)
Device fault status (normal or fault types).. Value can be found in the published state on the fault_state property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"fault_state": ""}. It's not possible to write (/set) this value.
Muted (text)
Device mute status (normal or mute types).. Value can be found in the published state on the muted property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"muted": ""}. It's not possible to write (/set) this value.
Trigger selftest (enum)
Trigger alarm self-check.. Value will not be published in the state. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"trigger_selftest": "VALUE"}. The possible values are: test.
Temporary mute (binary)
Silence the alarm temporarily. Value can be found in the published state on the temporary_mute property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"temporary_mute": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temporary_mute": VALUE}. If value equals true temporary mute is ON, if false OFF.
Heartbeat indicator (binary)
Enable/disable the indicator on product. Value can be found in the published state on the heartbeat_indicator property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"heartbeat_indicator": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"heartbeat_indicator": VALUE}. If value equals true heartbeat indicator is ON, if false OFF.
Interconnectable (binary)
used for interconnection automation.. Value can be found in the published state on the interconnectable property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"interconnectable": ""}. It's not possible to write (/set) this value. If value equals true interconnectable is ON, if false OFF.
Smoke level (numeric)
smoke level. Value can be found in the published state on the smoke_level property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"smoke_level": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 20.
Smoke unit (enum)
smoke level unit. Value can be found in the published state on the smoke_unit property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"smoke_unit": ""}. It's not possible to write (/set) this value. The possible values are: dB/m, %ft OBS.
Chamber contamination (enum)
it indicates that how serious the smoke chamber get contaminated.. Value can be found in the published state on the chamber_contamination property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"chamber_contamination": ""}. It's not possible to write (/set) this value. The possible values are: normal, light_contamination, medium_contamination, critical_contamination.
Link available (enum)
used for interconnection automation.. Value can be found in the published state on the link_available property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"link_available": ""}. It's not possible to write (/set) this value. The possible values are: inactive, smoke_active, co_active, gas_active, heat_active.
Siren for automation only (enum)
siren effect. Value can be found in the published state on the siren_for_automation_only property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"siren_for_automation_only": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"siren_for_automation_only": "VALUE"}. The possible values are: stop, smoke_siren, co_siren.
Temperature offset (numeric)
used for temperature offset, unit: ℃. Value can be found in the published state on the temperature_offset property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"temperature_offset": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_offset": VALUE}. The minimal value is -15 and the maximum value is 15.
Reported packages (numeric)
for diagnostic purpose, how many zigbee packages has the reported in a day.. Value can be found in the published state on the reported_packages property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"reported_packages": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 60000.
Rejoin count (numeric)
for diagnostic purpose, how many times has the product rejoined to zigbee network.. Value can be found in the published state on the rejoin_count property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"rejoin_count": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 60000.
Reboot count (numeric)
for diagnostic purpose, how many times has the product rebooted.. Value can be found in the published state on the reboot_count property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"reboot_count": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 60000.