Lidl HG08673-BS
Model | HG08673-BS |
Vendor | Lidl |
Description | Silvercrest smart plug with power monitoring (BS) |
Exposes | switch (state), power_outage_memory, indicator_mode, power, current, voltage, energy, lock (state), linkquality |
Picture |
Notes
Reset energy
To reset Sum of consumed energy
, use the Dev console and execute:Endpoint
: 1
Cluster
: 0x00
Command
: 0
Payload
: (don't change this)
Next time the plug gets polled, Sum of consumed energy
will start from zero again.
Pairing
Perform a factory reset by holding down the switch on the plug continuously for 5 seconds. The LED will start blinking and the device will enter pairing mode.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
measurement_poll_interval
: Only the energy value is polled for this device. The value must be a number with a minimum value of-1
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Power outage memory (enum)
Recover state after power outage. Value can be found in the published state on the power_outage_memory
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_outage_memory": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_outage_memory": NEW_VALUE}
. The possible values are: on
, off
, restore
.
Indicator mode (enum)
LED indicator mode. Value can be found in the published state on the indicator_mode
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"indicator_mode": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"indicator_mode": NEW_VALUE}
. The possible values are: off
, off/on
, on/off
, on
.
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is W
.
Current (numeric)
Instantaneous measured electrical current. Value can be found in the published state on the current
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is A
.
Voltage (numeric)
Measured electrical potential value. Value can be found in the published state on the voltage
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is V
.
Energy (numeric)
Sum of consumed energy. Value can be found in the published state on the energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Child lock (lock)
The current state of this lock is in the published state under the child_lock
property (value is LOCK
or UNLOCK
). To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"child_lock": "LOCK"}
or {"child_lock": "UNLOCK"}
. It's not possible to read (/get
) this value.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.