To contribute to this page, edit the following file

Lidl HG06463A #

Model HG06463A
Vendor Lidl
Description Livarno Lux E27 ST64 filament bulb
Exposes light (state, brightness), linkquality
Picture Lidl HG06463A

Notes #

Pairing #

Factory reset the light bulb. After resetting the bulb will automatically connect.

Factory reset the light bulb. After resetting the bulb will automatically connect.

One option that might work is to use (very) short “on’s” and a little bit longer “off’s”, where you kill the light as soon as the bulb shows signs of turning on. Start with bulb on, then off, and then 3 “on’s”, wait in the 3rd ON state. Alternatively, start with the bulb on, and then repeat the off on sequence as above, but wait 2-3 seconds in each state (on and off). When in pairing state, the bulb will flash.

Device type specific configuration #

How to use device type specific configuration

Exposes #

Light #

This light supports the following features: state, brightness.

Transition #

For all of the above mentioned features it is possible to do a transition of the value over time. To do this add an additional property transition to the payload which is the transition time in seconds. Examples: {"brightness":156,"transition":3}, {"color_temp":241,"transition":1}.

Moving/stepping #

Instead of setting a value (e.g. brightness) directly it is also possible to:

The direction of move and step can be either up or down, provide a negative value to move/step down, a positive value to move/step up. To do this send a payload like below to zigbee2mqtt/FRIENDLY_NAME/set

NOTE: brightness move/step will stop at the minimum brightness and won’t turn on the light when it’s off. In this case use brightness_move_onoff/brightness_step_onoff

{
  "brightness_move": -40, // Starts moving brightness down at 40 units per second
  "brightness_move": 0, // Stop moving brightness
  "brightness_step": 40 // Increases brightness by 40
}

Linkquality (numeric) #

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.

Manual Home Assistant configuration #

Although Home Assistant integration through MQTT discovery is preferred, manual integration is possible with the following configuration:

light:
  - platform: "mqtt"
    state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
    availability_topic: "zigbee2mqtt/bridge/state"
    brightness: true
    schema: "json"
    command_topic: "zigbee2mqtt/<FRIENDLY_NAME>/set"
    brightness_scale: 254

sensor:
  - platform: "mqtt"
    state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
    availability_topic: "zigbee2mqtt/bridge/state"
    value_template: "{{ value_json.linkquality }}"
    unit_of_measurement: "lqi"
    enabled_by_default: false
    icon: "mdi:signal"
    state_class: "measurement"