Bacchus Flower_Sensor_v4
| Model | Flower_Sensor_v4 |
| Vendor | Bacchus |
| Description | Flower soil moisture sensor |
| Exposes | soil_moisture, temperature, illuminance, report_delay, threshold, tx_radio_power, smart_sleep, thermal_compensation, battery, voltage |
| Picture | ![]() |
Options
How to use device type specific configuration
soil_moisture_calibration: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.soil_moisture_precision: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0and with a maximum value of3illuminance_calibration: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.illuminance_raw: Expose the raw illuminance value. The value must betrueorfalse
Exposes
Soil moisture (numeric)
Measured soil moisture value. Value can be found in the published state on the soil_moisture property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.
Illuminance (numeric)
Measured illuminance. Value can be found in the published state on the illuminance property. It's not possible to read (/get) or write (/set) this value. The unit of this value is lx.
Report delay (numeric)
Reporting interval. Value can be found in the published state on the report_delay property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"report_delay": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"report_delay": NEW_VALUE}. The minimal value is 1 and the maximum value is 600. The unit of this value is min.
Threshold (numeric)
Reporting interval. Value can be found in the published state on the threshold property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"threshold": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"threshold": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Tx radio power (enum)
Set TX Radio Power, dbm. Value can be found in the published state on the tx_radio_power property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"tx_radio_power": NEW_VALUE}. The possible values are: 10dbm, 19dbm.
Smart sleep (binary)
Enable Smart Sleep, short wakeup every 6 seconds. Value can be found in the published state on the smart_sleep property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"smart_sleep": NEW_VALUE}. If value equals ON smart sleep is ON, if OFF OFF.
Thermal compensation (binary)
Thermal compensation. Value can be found in the published state on the thermal_compensation property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"thermal_compensation": NEW_VALUE}. If value equals ON thermal compensation is ON, if OFF OFF.
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"battery": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.
Voltage (numeric)
Reported battery voltage in millivolts. Value can be found in the published state on the voltage property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"voltage": ""}. It's not possible to write (/set) this value. The unit of this value is mV.