  • Zigbee

    • Zigbee network
    • Improve network range and stability
    • Sniff Zigbee traffic
    • Create a CC2530 router
  • Support new devices

    • Support new devices
    • Support new Tuya devices
    • Find Tuya Data Points
  • Remote Adapter

    • Connect to a remote adapter
    • Connect to a remote Sonoff ZBBridge
  • More

    • 3D cases
    • External converters
    • External extensions
    • Switch to the dev branch
    • Get Tuya and Xiaomi OTA url
  • Forum
  • Discord
  • Issues
  • Donate
GitHub
GitHub (docs)

Excellux EZ-500FS

ModelEZ-500FS
VendorExcellux
DescriptionSplit-type sensor for detecting soil moisture, temperature and humidity
Exposesbattery, probe_temperature_warning, temperature_warning, humidity_warning, moisture_warning, probe_temperature, moisture, temperature, humidity, sampling_interval, probe_temperature_calibration, probe_temperature_v0_set, probe_temperature_v1_set, temperature_calibration, temperature_v0_set, temperature_v1_set, humidity_calibration, humidity_v0_set, humidity_v1_set, moisture_calibration, moisture_v0_set, moisture_v1_set
PictureExcellux EZ-500FS

Options

How to use device type specific configuration

  • time_start: Reply to Tuya-specific time synchronization requests: "1970" - Reply with seconds since 1970/01/01 (recommended, should stop the device from asking), "2000" - Reply with seconds since 2000/01/01 (use if the weekday is wrong with 1970), "off" - Don't reply (use if replying causes too much traffic). Default for this device: "off". The value must be one of 1970, 2000, off

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a maximum value of 3

  • humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.

  • humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a maximum value of 3

Exposes

Battery (numeric)

Battery level. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Probe temperature warning (enum)

Probe temperature sensor warning. Low: temperature is lower than v0 and v1. High: temperature is higher than v0 and v1. Value can be found in the published state on the probe_temperature_warning property. It's not possible to read (/get) or write (/set) this value. The possible values are: none, low, high.

Temperature warning (enum)

Temperature warning. Low: temperature is lower than v0 and v1. High: temperature is higher than v0 and v1. Value can be found in the published state on the temperature_warning property. It's not possible to read (/get) or write (/set) this value. The possible values are: none, low, high.

Humidity warning (enum)

Humidity warning. Low: humidity is lower than v0 and v1. High: humidity is higher than v0 and v1. Value can be found in the published state on the humidity_warning property. It's not possible to read (/get) or write (/set) this value. The possible values are: none, low, high.

Moisture warning (enum)

Moisture warning. Low: Moisture is lower than v0 and v1. High: Moisture is higher than v0 and v1. Value can be found in the published state on the moisture_warning property. It's not possible to read (/get) or write (/set) this value. The possible values are: none, low, high.

Probe temperature (numeric)

Probe temperature sensor. Value can be found in the published state on the probe_temperature property. It's not possible to read (/get) or write (/set) this value. The minimal value is -40 and the maximum value is 120. The unit of this value is °C.

Moisture (numeric)

Soil moisture. Value can be found in the published state on the moisture property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Humidity (numeric)

Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.

Sampling interval (numeric)

Sampling interval. Value can be found in the published state on the sampling_interval property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"sampling_interval": NEW_VALUE}. The minimal value is 5 and the maximum value is 1200. The unit of this value is s.

Probe temperature calibration (numeric)

Probe temperature sensor calibration. Value can be found in the published state on the probe_temperature_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"probe_temperature_calibration": NEW_VALUE}. The minimal value is -2 and the maximum value is 2. The unit of this value is °C.

Probe temperature v0 set (numeric)

Probe temperature sensor v0 threshold setting. Value can be found in the published state on the probe_temperature_v0_set property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"probe_temperature_v0_set": NEW_VALUE}. The minimal value is -40 and the maximum value is 125. The unit of this value is °C.

Probe temperature v1 set (numeric)

Probe temperature sensor v1 threshold setting. Value can be found in the published state on the probe_temperature_v1_set property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"probe_temperature_v1_set": NEW_VALUE}. The minimal value is -40 and the maximum value is 125. The unit of this value is °C.

Temperature calibration (numeric)

Temperature calibration. Value can be found in the published state on the temperature_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_calibration": NEW_VALUE}. The minimal value is -2 and the maximum value is 2. The unit of this value is °C.

Temperature v0 set (numeric)

Temperature v0 threshold setting. Value can be found in the published state on the temperature_v0_set property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_v0_set": NEW_VALUE}. The minimal value is -40 and the maximum value is 85. The unit of this value is °C.

Temperature v1 set (numeric)

Temperature v1 threshold setting. Value can be found in the published state on the temperature_v1_set property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_v1_set": NEW_VALUE}. The minimal value is -40 and the maximum value is 85. The unit of this value is °C.

Humidity calibration (numeric)

Humidity calibration. Value can be found in the published state on the humidity_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_calibration": NEW_VALUE}. The minimal value is -10 and the maximum value is 10. The unit of this value is %.

Humidity v0 set (numeric)

Humidity v0 threshold setting. Value can be found in the published state on the humidity_v0_set property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_v0_set": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Humidity v1 set (numeric)

Humidity v1 threshold setting. Value can be found in the published state on the humidity_v1_set property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_v1_set": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Moisture calibration (numeric)

Coefficient 0.2~1.5. Higher for loose‑hard soil, lower for wet soft clay.. Value can be found in the published state on the moisture_calibration property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"moisture_calibration": NEW_VALUE}. The minimal value is 0.2 and the maximum value is 1.5.

Moisture v0 set (numeric)

Moisture v0 threshold setting. Value can be found in the published state on the moisture_v0_set property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"moisture_v0_set": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Moisture v1 set (numeric)

MMoisture v1 threshold setting. Value can be found in the published state on the moisture_v1_set property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"moisture_v1_set": NEW_VALUE}. The minimal value is 0 and the maximum value is 100. The unit of this value is %.