Zigbee2MQTTZigbee2MQTT
  • Getting started
  • Supported Adapters
  • Supported Devices
  • Installation
  • Configuration
  • Usage
  • FAQ
Devices
  • Zigbee

    • Zigbee network
    • Improve network range and stability
    • Secure your Zigbee network
    • Sniff Zigbee traffic
    • Create a CC2530 router
  • Support new devices

    • Support new devices
    • Support new Tuya devices
    • Find Tuya Data Points
  • Remote Adapter

    • Connect to a remote adapter
    • Connect to a remote Sonoff ZBBridge
  • More

    • 3D cases
    • External converters
    • External extensions
    • Switch to the dev branch
    • Get Tuya and Xiaomi OTA url
  • Forum
  • Discord
  • Issues
  • Donate
GitHub
GitHub (docs)
  • Getting started
  • Supported Adapters
  • Supported Devices
  • Installation
  • Configuration
  • Usage
  • FAQ
Devices
  • Zigbee

    • Zigbee network
    • Improve network range and stability
    • Secure your Zigbee network
    • Sniff Zigbee traffic
    • Create a CC2530 router
  • Support new devices

    • Support new devices
    • Support new Tuya devices
    • Find Tuya Data Points
  • Remote Adapter

    • Connect to a remote adapter
    • Connect to a remote Sonoff ZBBridge
  • More

    • 3D cases
    • External converters
    • External extensions
    • Switch to the dev branch
    • Get Tuya and Xiaomi OTA url
  • Forum
  • Discord
  • Issues
  • Donate
GitHub
GitHub (docs)

EFEKTA EFEKTA_TH_POW

ModelEFEKTA_TH_POW
VendorEFEKTA
DescriptionTemperature and humidity smart monitor with voltage detector
Exposesidentify, temperature, humidity, mains_voltage, battery, battery_low, lifetime, reading_interval, tx_radio_power, config_report_enable, comparison_previous_data, enabling_temperature_control, temperature_actions, high_temperature, low_temperature, enabling_humidity_control, humidity_actions, high_humidity, low_humidity
PictureEFEKTA EFEKTA_TH_POW

Options

How to use device type specific configuration

  • temperature_calibration: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.

  • temperature_precision: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a maximum value of 3

  • humidity_calibration: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.

  • humidity_precision: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of 0 and with a maximum value of 3

  • identify_timeout: Sets the duration of the identification procedure in seconds (i.e., how long the device would flash).The value ranges from 1 to 30 seconds (default: 3). The value must be a number with a minimum value of 1 and with a maximum value of 30

Exposes

Identify (enum)

Initiate device identification. Value will not be published in the state. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"identify": NEW_VALUE}. The possible values are: identify.

Temperature (numeric)

Measured temperature value. Value can be found in the published state on the temperature property. It's not possible to read (/get) or write (/set) this value. The unit of this value is °C.

Humidity (numeric)

Measured relative humidity. Value can be found in the published state on the humidity property. It's not possible to read (/get) or write (/set) this value. The unit of this value is %.

Mains voltage (numeric)

Mains voltage. Value can be found in the published state on the mains_voltage property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"mains_voltage": ""}. It's not possible to write (/set) this value. The unit of this value is V.

Battery (numeric)

Remaining battery in %. Value can be found in the published state on the battery property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"battery": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Battery low (binary)

Empty battery indicator. Value can be found in the published state on the battery_low property. It's not possible to read (/get) or write (/set) this value. If value equals true battery low is ON, if false OFF.

Lifetime (numeric)

Uptime. Value can be found in the published state on the lifetime property. It's not possible to read (/get) or write (/set) this value. The unit of this value is Hours.

Reading interval (numeric)

Setting the sensor reading interval in seconds, by default 5 seconds. Value can be found in the published state on the reading_interval property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"reading_interval": NEW_VALUE}. The minimal value is 3 and the maximum value is 300. The unit of this value is sec.

Tx radio power (enum)

Set TX Radio Power, dbm. Value can be found in the published state on the tx_radio_power property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"tx_radio_power": NEW_VALUE}. The possible values are: 4dbm, 19dbm.

Config report enable (binary)

Enable reporting based on reporting configuration. Value can be found in the published state on the config_report_enable property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"config_report_enable": NEW_VALUE}. If value equals ON config report enable is ON, if OFF OFF.

Comparison previous data (binary)

Enable сontrol of comparison with previous data. Value can be found in the published state on the comparison_previous_data property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"comparison_previous_data": NEW_VALUE}. If value equals ON comparison previous data is ON, if OFF OFF.

Enabling temperature control (binary)

Enables/disables Tempearure control. Value can be found in the published state on the enabling_temperature_control property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"enabling_temperature_control": NEW_VALUE}. If value equals ON enabling temperature control is ON, if OFF OFF.

Temperature actions (enum)

Heat or cool. Value can be found in the published state on the temperature_actions property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"temperature_actions": NEW_VALUE}. The possible values are: HEAT, COOL.

High temperature (numeric)

Setting High Temperature Border. Value can be found in the published state on the high_temperature property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"high_temperature": NEW_VALUE}. The minimal value is -40 and the maximum value is 90. The unit of this value is °C.

Low temperature (numeric)

Setting Low Temperature Border. Value can be found in the published state on the low_temperature property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"low_temperature": NEW_VALUE}. The minimal value is -40 and the maximum value is 90. The unit of this value is °C.

Enabling humidity control (binary)

Enables/disables Humidity control. Value can be found in the published state on the enabling_humidity_control property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"enabling_humidity_control": NEW_VALUE}. If value equals ON enabling humidity control is ON, if OFF OFF.

Humidity actions (enum)

Wet or dry. Value can be found in the published state on the humidity_actions property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"humidity_actions": NEW_VALUE}. The possible values are: WET, DRY.

High humidity (numeric)

Setting High Humidity Border. Value can be found in the published state on the high_humidity property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"high_humidity": NEW_VALUE}. The minimal value is 0 and the maximum value is 99. The unit of this value is %.

Low humidity (numeric)

Setting Low Humidity Border. Value can be found in the published state on the low_humidity property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"low_humidity": NEW_VALUE}. The minimal value is 0 and the maximum value is 99. The unit of this value is %.