Schneider Electric EER42000 #

Model EER42000
Vendor Schneider Electric
Description Zigbee load actuator with power meter
Exposes switch (state), power, energy, linkquality
Picture Schneider Electric EER42000

Notes #

Pairing #

This device by default only pairs to Wiser Gateways when the set button is pressed, to let it join normal HA gateways (like what Zigbee2MQTT uses) hold the set button down for 5 seconds, and release.

Exposes #

Switch #

The current state of this switch is in the published state under the state property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "ON"}, {"state": "OFF"} or {"state": "TOGGLE"}. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"state": ""}.

Power (numeric) #

Instantaneous measured power. Value can be found in the published state on the power property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is W.

Energy (numeric) #

Sum of consumed energy. Value can be found in the published state on the energy property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is kWh.

Linkquality (numeric) #

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.

Manual Home Assistant configuration #

Although Home Assistant integration through MQTT discovery is preferred, manual integration is possible with the following configuration:

switch:
  - platform: "mqtt"
    state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
    availability_topic: "zigbee2mqtt/bridge/state"
    payload_off: "OFF"
    payload_on: "ON"
    value_template: "{{ value_json.state }}"
    command_topic: "zigbee2mqtt/<FRIENDLY_NAME>/set"

sensor:
  - platform: "mqtt"
    state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
    availability_topic: "zigbee2mqtt/bridge/state"
    value_template: "{{ value_json.power }}"
    unit_of_measurement: "W"
    device_class: "power"
    state_class: "measurement"

sensor:
  - platform: "mqtt"
    state_topic: "zigbee2mqtt/<FRIENDLY_NAME>"
    availability_topic: "zigbee2mqtt/bridge/state"
    value_template: "{{ value_json.energy }}"
    unit_of_measurement: "kWh"
    device_class: "energy"
    state_class: "measurement"
    last_reset_topic: true
    last_reset_value_template: "1970-01-01T00:00:00+00:00"