Nova Digital CMR-1
| Model | CMR-1 |
| Vendor | Nova Digital |
| Description | Roller Blind Motor |
| Exposes | cover (state, position), reverse_direction, motor_fault, upper_stroke_limit, middle_stroke_limit, lower_stroke_limit, motor_working_mode |
| Picture | ![]() |
Options
How to use device type specific configuration
invert_cover: Inverts the cover position and state, false: open=100,close=0, true: open=0,close=100 (default false). The value must betrueorfalsetime_start: Reply to Tuya-specific time synchronization requests: "1970" - Reply with seconds since 1970/01/01 (recommended, should stop the device from asking), "2000" - Reply with seconds since 2000/01/01 (use if the weekday is wrong with 1970), "off" - Don't reply (use if replying causes too much traffic). Default for this device: "off". The value must be one of1970,2000,off
Exposes
Cover
The current state of this cover is in the published state under the state property (value is OPEN or CLOSE). To control this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"state": "OPEN"}, {"state": "CLOSE"}, {"state": "STOP"}. It's not possible to read (/get) this value. To change the position publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"position": VALUE} where VALUE is a number between 0 and 100.
Reverse direction (enum)
Reverse the motor direction. Value can be found in the published state on the reverse_direction property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"reverse_direction": NEW_VALUE}. The possible values are: forward, back.
Motor fault (binary)
Motor Fault. Value can be found in the published state on the motor_fault property. It's not possible to read (/get) or write (/set) this value. If value equals true motor fault is ON, if false OFF.
Upper stroke limit (enum)
Set or Reset the upper stroke limit. Value can be found in the published state on the upper_stroke_limit property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"upper_stroke_limit": NEW_VALUE}. The possible values are: SET, RESET.
Middle stroke limit (enum)
Set or Reset the middle stroke limit. Value can be found in the published state on the middle_stroke_limit property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"middle_stroke_limit": NEW_VALUE}. The possible values are: SET, RESET.
Lower stroke limit (enum)
Set or Reset the lower stroke limit. Value can be found in the published state on the lower_stroke_limit property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"lower_stroke_limit": NEW_VALUE}. The possible values are: SET, RESET.
Motor working mode (enum)
Motor operating mode. Value can be found in the published state on the motor_working_mode property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"motor_working_mode": NEW_VALUE}. The possible values are: continuous, intermittently.