Bosch BSP-FZ2
Model | BSP-FZ2 |
Vendor | Bosch |
Description | Plug compact EU |
Exposes | switch (state), power_on_behavior, power, energy, linkquality |
Picture |
Notes
Pairing
To pair this device you have to install the device via its installation code which you can get by scanning the QR-code sticker on the physical device with your smartphone. Then get the device into pairing mode. In zigbee2mqtt navigate to "Settings" --> "Tools" and click on "Add install code". Paste the code you got from the QR-code and confirm by clicking "OK" which will get zigbee2mqtt into pairing mode automatically. Wait for your device to be joined.
Factory resetting
To factory reset the device unplug it from the mains. While pressing and holding the device's main button on the top, plug it in again. As soon as the device's LED is starting to blink orange, release the main button and press and hold it again until the device's LED is lighting up green. The device will then restart and look for a Zigbee network to join. In case something went wrong, the device's LED will start to blink red. The process has then to be start all over again.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Power-on behavior (enum)
Controls the behavior when the device is powered on after power loss. Value can be found in the published state on the power_on_behavior
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
. The possible values are: off
, on
, toggle
, previous
.
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power": ""}
. It's not possible to write (/set
) this value. The unit of this value is W
.
Energy (numeric)
Sum of consumed energy. Value can be found in the published state on the energy
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"energy": ""}
. It's not possible to write (/set
) this value. The unit of this value is kWh
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.