To contribute to this page, edit the following file

Moes BRT-100-TRV #

Model BRT-100-TRV
Vendor Moes
Description Thermostatic radiator valve
Exposes battery, lock (state), eco_mode, eco_temperature, max_temperature, min_temperature, position, switch (state), window, climate (local_temperature, current_heating_setpoint, local_temperature_calibration, preset), programming_mode, boost_heating, boost_heating_countdown, boost_heating_countdown_time_set, linkquality
Picture Moes BRT-100-TRV

Notes #

None

OTA updates #

This device supports OTA updates, for more information see OTA updates.

Exposes #

Battery (numeric) #

Remaining battery in %. Value can be found in the published state on the battery property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Lock #

The current state of this lock is in the published state under the child_lock property (value is LOCK or UNLOCK). To control this lock publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"child_lock": "LOCK"} or {"child_lock": "UNLOCK"}. It’s not possible to read (/get) this value.

Eco_mode (binary) #

ECO mode (energy saving mode). Value can be found in the published state on the eco_mode property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"eco_mode": NEW_VALUE}. If value equals ON eco_mode is ON, if OFF OFF.

Eco_temperature (numeric) #

Eco temperature. Value can be found in the published state on the eco_temperature property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"eco_temperature": NEW_VALUE}. The unit of this value is °C.

Max_temperature (numeric) #

Maximum temperature. Value can be found in the published state on the max_temperature property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"max_temperature": NEW_VALUE}. The unit of this value is °C.

Min_temperature (numeric) #

Minimum temperature. Value can be found in the published state on the min_temperature property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"min_temperature": NEW_VALUE}. The unit of this value is °C.

Position (numeric) #

Position. Value can be found in the published state on the position property. It’s not possible to read (/get) or write (/set) this value. The unit of this value is %.

Switch #

The current state of this switch is in the published state under the window_detection property (value is ON or OFF). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"window_detection": "ON"}, {"window_detection": "OFF"} or {"window_detection": "TOGGLE"}. It’s not possible to read (/get) this value.

Window (binary) #

Window status closed or open . Value can be found in the published state on the window property. It’s not possible to read (/get) or write (/set) this value. If value equals CLOSED window is ON, if OPEN OFF.

Climate #

This climate device supports the following features: local_temperature, current_heating_setpoint, local_temperature_calibration, preset.

Programming_mode (composite) #

Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set with payload {"undefined": {"program_weekday": VALUE, "program_saturday": VALUE, "program_sunday": VALUE}}

Boost_heating (binary) #

Boost Heating: press and hold “+” for 3 seconds, the device will enter the boost heating mode, and the ▷╵◁ will flash. The countdown will be displayed in the APP. Value can be found in the published state on the boost_heating property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"boost_heating": NEW_VALUE}. If value equals ON boost_heating is ON, if OFF OFF.

Boost_heating_countdown (numeric) #

Countdown in minutes. Value can be found in the published state on the boost_heating_countdown property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"boost_heating_countdown": NEW_VALUE}. The unit of this value is min.

Boost_heating_countdown_time_set (numeric) #

Boost Time Setting 100 sec - 900 sec, (default = 300 sec). Value can be found in the published state on the boost_heating_countdown_time_set property. It’s not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"boost_heating_countdown_time_set": NEW_VALUE}. The unit of this value is second.

Linkquality (numeric) #

Link quality (signal strength). Value can be found in the published state on the linkquality property. It’s not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.