RTX ZCR1-40EM
Model | ZCR1-40EM |
Vendor | RTX |
Description | Zigbee DIN energy meter |
Exposes | switch (state), ac_frequency, energy, power, power_factor, voltage, current, produced_energy, linkquality |
Picture | ![]() |
Options
How to use device type specific configuration
energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. The value must be a number with a minimum value of0
and with a with a maximum value of3
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
. It's not possible to read (/get
) this value.
AC frequency (numeric)
Measured electrical AC frequency. Value can be found in the published state on the ac_frequency
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is Hz
.
Energy (numeric)
Sum of consumed energy. Value can be found in the published state on the energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is W
.
Power factor (numeric)
Instantaneous measured power factor. Value can be found in the published state on the power_factor
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Voltage (numeric)
Measured electrical potential value. Value can be found in the published state on the voltage
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is V
.
Current (numeric)
Instantaneous measured electrical current. Value can be found in the published state on the current
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is A
.
Produced energy (numeric)
Sum of produced energy. Value can be found in the published state on the produced_energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.