Climax SD-8SCZBS

ModelSD-8SCZBS
VendorClimax
DescriptionSmoke detector
Exposessmoke, battery, battery_low, tamper, warning, linkquality
PictureClimax SD-8SCZBS

Exposes

Smoke (binary)

Indicates whether the device detected smoke. Value can be found in the published state on the smoke property. It's not possible to read (/get) or write (/set) this value. If value equals true smoke is ON, if false OFF.

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Battery low (binary)

Indicates if the battery of this device is almost empty. Value can be found in the published state on the battery_low property. It's not possible to read (/get) or write (/set) this value. If value equals true battery low is ON, if false OFF.

Tamper (binary)

Indicates whether the device is tampered. Value can be found in the published state on the tamper property. It's not possible to read (/get) or write (/set) this value. If value equals true tamper is ON, if false OFF.

Warning (composite)

Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set with payload {"warning": {"mode": VALUE, "level": VALUE, "strobe_level": VALUE, "strobe": VALUE, "strobe_duty_cycle": VALUE, "duration": VALUE}}

  • mode (enum): Mode of the warning (sound effect) allowed values: stop, burglar, fire, emergency, police_panic, fire_panic, emergency_panic
  • level (enum): Sound level allowed values: low, medium, high, very_high
  • strobe_level (enum): Intensity of the strobe allowed values: low, medium, high, very_high
  • strobe (binary): Turn on/off the strobe (light) during warning allowed values: true or false
  • strobe_duty_cycle (numeric): Length of the flash cycle max value is 10
  • duration (numeric): Duration in seconds of the alarm unit is s

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.