Vareo HYT001ZB
| Model | HYT001ZB |
| Vendor | Vareo |
| Description | Smart thermostat for electric floor heating or boilers |
| Exposes | climate (current_heating_setpoint, local_temperature, local_temperature_calibration, system_mode, preset, running_state), hysteresis, sensor_type, holiday_temperature, holiday_days, fault |
| Picture | ![]() |
Options
How to use device type specific configuration
time_start: Reply to Tuya-specific time synchronization requests: "1970" - Reply with seconds since 1970/01/01 (recommended, should stop the device from asking), "2000" - Reply with seconds since 2000/01/01 (use if the weekday is wrong with 1970), "off" - Don't reply (use if replying causes too much traffic). Default for this device: "off". The value must be one of1970,2000,off
Exposes
Climate
This climate device supports the following features: current_heating_setpoint, local_temperature, local_temperature_calibration, system_mode, preset, running_state.
current_heating_setpoint: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"current_heating_setpoint": VALUE}whereVALUEis the °C between5and35. Reading (/get) this attribute is not possible.local_temperature: Current temperature measured on the device (in °C). Reading (/get) this attribute is not possible.system_mode: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"system_mode": "VALUE"}whereVALUEis one of:off,heat. Reading (/get) this attribute is not possible.preset: Mode of this device (similar to system_mode). To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"preset": "VALUE"}whereVALUEis one of:manual,program,holiday,temporary. Reading (/get) this attribute is not possible.running_state: The current running state. Possible values are:idle,heat. Reading (/get) this attribute is not possible.local_temperature_calibration: Offset to add/subtract to the local temperature. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/setwith payload{"local_temperature_calibration": VALUE}.The minimal value is-9and the maximum value is9with a step size of0.5.
Hysteresis (numeric)
Switching hysteresis. Value can be found in the published state on the hysteresis property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"hysteresis": VALUE}. The minimal value is 0.5 and the maximum value is 5. The unit of this value is °C.
Sensor type (enum)
Temperature sensor selection. Value can be found in the published state on the sensor_type property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"sensor_type": "VALUE"}. The possible values are: internal, external, both.
Holiday temperature (numeric)
Setpoint in holiday mode. Value can be found in the published state on the holiday_temperature property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"holiday_temperature": VALUE}. The minimal value is 5 and the maximum value is 35. The unit of this value is °C.
Holiday days (numeric)
Holiday mode duration. Value can be found in the published state on the holiday_days property. It's not possible to read (/get) this value. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"holiday_days": VALUE}. The minimal value is 1 and the maximum value is 30. The unit of this value is d.
Fault (numeric)
Fault bitmap (4 = external sensor error). Value can be found in the published state on the fault property. It's not possible to read (/get) or write (/set) this value.