SMaBiT (Bitron Video) AV2010/32

ModelAV2010/32
VendorSMaBiT (Bitron Video)
DescriptionWireless wall thermostat with relay
Exposesclimate (occupied_heating_setpoint, local_temperature, system_mode, running_state, local_temperature_calibration, control_sequence_of_operation), keypad_lockout, hysteresis, battery, battery_low, linkquality
PictureSMaBiT (Bitron Video) AV2010/32

Notes

Heating or cooling

This thermostat can work in a heating or cooling mode. You can switch between them by setting control_sequence_of_operation to either 'heating_only' (default after factory reset) or 'cooling_only'.

The exposed data will adapt dynamically, but it will require a Zigbee2MQTT restart before it gets updated after changing control_sequence_of_operation.

Options

How to use device type specific configuration

  • thermostat_unit: Controls the temperature unit of the thermostat (default celsius). The value must be one of celsius, fahrenheit

  • legacy: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must be true or false

Exposes

Climate

This climate device supports the following features: occupied_heating_setpoint, local_temperature, system_mode, running_state, local_temperature_calibration, control_sequence_of_operation.

  • occupied_heating_setpoint: Temperature setpoint. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"occupied_heating_setpoint": VALUE} where VALUE is the °C between 7 and 30. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"occupied_heating_setpoint": ""}.
  • local_temperature: Current temperature measured on the device (in °C). To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"local_temperature": ""}.
  • system_mode: Mode of this device. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"system_mode": VALUE} where VALUE is one of: off, heat. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"system_mode": ""}.
  • running_state: The current running state. Possible values are: idle, heat. To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"running_state": ""}.
  • local_temperature_calibration: Offset to add/subtract to the local temperature. To control publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"local_temperature_calibration": VALUE}.To read send a message to zigbee2mqtt/FRIENDLY_NAME/get with payload {"local_temperature": ""}.The minimal value is -12.8 and the maximum value is 12.7 with a step size of 0.1.

Keypad lockout (enum)

Enables/disables physical input on the device. Value can be found in the published state on the keypad_lockout property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"keypad_lockout": ""}. To write (/set) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set with payload {"keypad_lockout": NEW_VALUE}. The possible values are: unlock, lock1, lock2.

Hysteresis (composite)

Set thermostat hysteresis low and high trigger values. (1 = 0.01ºC). Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set with payload {"hysteresis": {"low": VALUE, "high": VALUE}} To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"hysteresis": ""}.

  • low (numeric)
  • high (numeric)

Battery (numeric)

Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery property. To read (/get) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get with payload {"battery": ""}. It's not possible to write (/set) this value. The minimal value is 0 and the maximum value is 100. The unit of this value is %.

Battery low (binary)

Indicates if the battery of this device is almost empty. Value can be found in the published state on the battery_low property. It's not possible to read (/get) or write (/set) this value. If value equals true battery low is ON, if false OFF.

Linkquality (numeric)

Link quality (signal strength). Value can be found in the published state on the linkquality property. It's not possible to read (/get) or write (/set) this value. The minimal value is 0 and the maximum value is 255. The unit of this value is lqi.